Peek LPM-33-E Cabinet Modem
 

ALL MODEMS ARE NOT ALIKE!
Commercially available modems are generally not suitable for use in roadside applications. The temptation is strong to use least-cost modems, but Peek and its customers have found out through direct experience that commercial indoor modems, and even “industrial” modems, can have low reliability in field use.

That’s why Peek offers the LPM 33, specifically designed to provide data communications in roadside applications requiring remote access via standard dial access telephone service. It is
designed to meet the rigors imposed by extreme outdoor data collection and control cabinet environments. It is designed to operate over a temperature range of -40ºF to +162ºF (-40ºC to
+72ºC).

The LPM-33 can be powered by any source in the range from 5 to 36 Vdc. It features a low power standby mode that allows it to be battery powered. In standby mode, the LPM-33 requires less than 0.5mA of current at 12 Vdc. A solar panel-charged battery provides a fully satisfactory method of powering the LPM 33. Alternatively, the LPM 33 can be powered by a nominal 12 Vac from an available AC to DC wall mount transformer for use with any 120 VAC outlet.

Baud rates up to 33,600 are supported by the LPM 33. It is fully compatible with applicable Bell and CCITT standards, including those for error correction and data compression. The LPM 33 will operate in auto-answer and originate modes. The LPM 33 uses several timers to reduce net power consumption in typical applications. Sixty seconds after the termination of ringing voltage or 120 seconds after stopping of DTE data the LPM 33 will automatically revert to its low power standby mode. Standby mode will also occur 10 seconds after the loss of carrier is detected. The standby mode of the LPM 33 can be disabled, leaving the modem in continuous active mode.

 

 

 

LPM-33-E Modem

(Click image to enlarge)


Two Year Limited Warranty

Peek Traffic, Inc. warrants this product against manufacturing defects in materials and workmanship for two years from date of shipment from Peek. Specific contracts and regional laws may vary or alter these terms.


Additional Information

 

Specifications

 

 

  Modem Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . .   CCITT: V.34, V.32 bis, V.32, V.22 bis, V.22, V.21
Bell: 103, 212A
  Error Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . .   MNP 2-4, LAP-M
  Data Compression . . . . . . . . . . . . . . . . . . . . . . . . . . . .   MNP 5, V.42 bis
  Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . .   Hayes AT; Additional AT commands for data compression, error correction, cellular operation
  Interface to DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . .   Type: RS-232, DB 25 connector
Speed: Auto-detects with AT command, up to
115,200 Baud
Signaling: N-8-1
  Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . .   Speed:Baud rates to 33,600
Type: Auto-answer and originate
  Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2, set to factory default, user-definable, stored in non-volatile E2PROM
  Mode Control . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

Standby (normal): Awaiting ringing voltage or DTE
data, flashing green LED.

Standby to Active: Transitions within 6 seconds of
ringing voltage or 200 msec of DTE data, LED on
steady

Answer: After transition to active mode answers call
in accordance with S0 register setting for ring delay
Disconnect: Loss of carrier, DTR drop or on-hook AT
command

Active to Standby (selectable link controlled):
Active Connection – 10 seconds after loss of carrier;

No Connection – 60 seconds after last ring or 120
seconds after last DTE data

  Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . .   nternal: Jumper JP1 disables standby operation if
jumper is on
External: All operational control is via RS-232
connector
  LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . .   Standby: green, flashes awaiting call
Ringing: red
Send Data: red
Receive Data: red
Carrier Detect: red
Off Hook: red
  Power . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

Voltage:
5.0 to 36 Vdc; 12 VDC typical; wall mount transformer for 120 VAC source - Stancor STA 4112A.

Consumption:
Standby – 0.5mA @ 12 VDC maximum;
Active – 85 mA @ 12 VDC typical

  Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . .   Size: 1.9” H x 5.3” W x 8.6” D
Weight: 20 oz.
  Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . .   Storage: -40ºF to +185ºF (-40ºC to +85ºC)
Operating: -40ºF to +162ºF (-40ºC to +72ºC)
Humidity: 0 to 95%, non-condensing
       